Next Article in Journal
The Impact of Caregiver Pressure to Eat on Food Neophobia in Children with Autism Spectrum Disorder: A Cross-Sectional Study
Previous Article in Journal
Changes in Body Weight and Risk Factors for Overweight and Obesity in 5–6-Year-Old Children Attending School in Geneva
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Dependence of Successful Airway Management in Neonatal Simulation Manikins on the Type of Supraglottic Airway Device and Providers’ Backgrounds

1
Department of Pediatrics and Neonatology, Toyohashi Municipal Hospital, 50 Aza Hakken Nishi, Aotake-cho, Toyohashi 441-8570, Japan
2
Department of Pediatrics and Neonatology, Shizuoka Saiseikai General Hospital, Shizuoka 422-8527, Japan
3
Department of Pediatrics, Hamamatsu University School of Medicine, Hamamatsu 431-3192, Japan
4
Center for Human Development and Family Science, Department of Pediatrics and Neonatology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho, Nagoya 467-8601, Japan
*
Author to whom correspondence should be addressed.
Children 2024, 11(5), 530; https://doi.org/10.3390/children11050530
Submission received: 13 March 2024 / Revised: 24 April 2024 / Accepted: 25 April 2024 / Published: 28 April 2024
(This article belongs to the Section Pediatric Neonatology)

Abstract

:
Supraglottic airway devices such as laryngeal masks and i-gels are useful for airway management. The i-gel is a relatively new device that replaces the air-inflated cuff of the laryngeal mask with a gel-filled cuff. It remains unclear which device is more effective for neonatal resuscitation. We aimed to evaluate the dependence of successful airway management in neonatal simulators on the device type and providers’ backgrounds. Ninety-one healthcare providers performed four attempts at airway management using a laryngeal mask and i-gel in two types of neonatal manikins. The dependence of successful insertions within 16.7 s (75th percentile of all successful insertions) on the device type and providers’ specialty, years of healthcare service, and completion of the neonatal resuscitation training course was assessed. Successful insertion (p = 0.001) and insertion time (p = 0.003) were associated with using the i-gel vs. laryngeal mask. The providers’ backgrounds were not associated with the outcome. Using the i-gel was associated with more successful airway management than laryngeal masks using neonatal manikins. Considering the limited effect of the provider’s specialty and experience, using the i-gel as the first-choice device in neonatal resuscitation may be advantageous. Prospective studies are warranted to compare these devices in the clinical setting.

1. Introduction

Although most newborn infants successfully transition from intrauterine to extrauterine life without special help, approximately one in ten newborn infants require some form of medical assistance before spontaneous breathing is successfully established, and approximately 1 in 100 newborn infants require extensive cardiopulmonary resuscitation [1]. Positive pressure ventilation plays a pivotal role in neonatal resuscitation, given that respiratory failure typically precedes cardiac failure in newborn infants. Ineffective positive-pressure ventilation over prolonged periods could lead to the need for advanced resuscitation, including intubation, chest compressions, and adrenaline administration. Notably, every 30 s delay in initiating efficient ventilation is associated with a 16% increase in the risk of mortality or morbidity [2]. However, the optimal interface for administering positive pressure ventilation during the initial stages of resuscitation remains unclear.
Bag-and-mask ventilation is the most common form of positive-pressure ventilation [1]. Although a correctly executed bag-and-mask procedure offers ventilation comparable to that achieved with a tracheal tube, this technique requires training and experience. Similarly, tracheal tube intubation inherently involves a balance between the potential benefits and risks. A comprehensive registry study encompassing over 2600 intubation episodes in academic neonatal units highlighted significant challenges: severe oxygen desaturation, defined as a reduction of 20% or more from baseline oxygen saturation levels, in 41% of these episodes [3]. Successful intubation on the first attempt occurred in only half of the patients. A multivariable analysis within the registry study revealed that an increasing number of intubation attempts was correlated with a significantly heightened risk of adverse events (adjusted odds ratio [OR] 1.87, 95% confidence interval [CI] 1.63–2.14). Clinicians must consider alternative methods after an initial unsuccessful intubation attempt to avoid escalating the risk of harm through repeated failed attempts.
Laryngeal masks and other types of supraglottic airway devices are increasingly used for neonatal resuscitation. Global practice guidelines recommend the use of supraglottic airway devices for resuscitation of term and preterm newborns delivered ≥ 34 weeks gestation when tracheal intubation is not successful or feasible [1]. Furthermore, a recent study on late preterm and term infants reported that the time to spontaneous breathing was shorter with the use of supraglottic airway devices than with a face mask [4]. Consequently, the current guidelines suggest that supraglottic airway devices may be used in the place of face masks for newborns receiving positive pressure ventilation after delivery if the resources and training are available [5].
Since the introduction of the first laryngeal mask in 1983 [6], many revisions have been made to supraglottic airway devices to improve the safety and efficacy of airway management [7]. While the classical laryngeal mask must be inflated before use, the i-gel (Intersurgical Ltd., Wokingham, Berkshire, UK) has improved utility by replacing the air-inflatable cuff with a gel-filled ergonomic cuff (Figure 1).
Several studies have compared the effectiveness of laryngeal masks and i-gels in anesthetized children and found similar success rates [8,9,10,11,12,13,14,15]. However, studies have reported conflicting findings regarding insertion time. Several studies have demonstrated that the insertion time was shorter with the i-gel than with a laryngeal mask [8,10,14], whereas other studies reported similar [9,11] or longer [12,13,15] insertion times with the i-gel than with a laryngeal mask. Considering that the backgrounds of the patients and providers differed between these studies, these conflicting findings suggest that the effectiveness of airway management using a laryngeal mask and i-gel varies according to the patient type, procedure (resuscitation or anesthesia), and the provider’s background. Furthermore, these studies focused on airway management in children undergoing general anesthesia; therefore, little is known about airway management in newborn infants who need to be resuscitated shortly after birth. With further information on the dependence of successful airway management on the type of supraglottic airway device, background of newborn infants, and experience of resuscitation providers, the quality and efficacy of neonatal resuscitation may be significantly improved.
This study aimed to assess the dependence of successful laryngeal mask and i-gel insertion on the specialty, career, and experience of the resuscitation provider using neonatal simulation manikins.

2. Materials and Methods

This was a crossover randomized trial using two types of supraglottic airway devices in two types of neonatal simulation manikin. The study protocol was approved by the Institutional Review Board of Shizuoka Saiseikai General Hospital (#20231601). Participants were recruited from healthcare professionals who are currently working, training, or have previous work experience in the NICU or pediatric wards at Shizuoka Saiseikai General Hospital, which admits approximately 300 newborns to the NICU annually, with around 100 newborns receiving mechanical ventilation. Written informed consent was obtained from all participants.

2.1. Devices Used

Two types of supraglottic airway devices were used, i-gel size 1 and laryngeal mask (standard laryngeal mask, Solus, Intersurgical Ltd., Wokingham, Berkshire, UK) size 1. For neonatal simulation manikins, the Neonatal Resuscitation Model LM-089 (Koken Co., Ltd., Bunkyo-ku, Tokyo, Japan) and Laerdal Neonatal Intubation Trainer (Laerdal Medical., Stavanger, Norway) were used (Figure 1).

2.2. Study Procedures

First, the participants were provided with the study procedures and instructed on how to use the laryngeal mask and the i-gel using printed instructions (Figure 1). Subsequently, a member of the study team, who was a qualified instructor in the neonatal cardiopulmonary resuscitation (NCPR) training course [16], demonstrated the insertion of each supraglottic airway device into both manikins. The water-soluble lubrication was used as instructed for each supraglottic airway device. All participants performed four insertion attempts using both types of supraglottic airway devices and manikins (Figure 1), the order of which was randomized using the RAND function of the spreadsheet software (Microsoft Excel 2013, Microsoft Corporation, Redmond, WA, USA). Two staff members observed each insertion attempt. The participants were instructed to declare the commencement of the insertion procedure, pick up the supraglottic airway device, and inform the staff when their attempts at insertion were complete. The time spent from the commencement of the procedure to its completion was recorded by a staff member of the study team. The study staff then connected the supraglottic airway device to a bag valve mask (Twenty-One Manual Resuscitator, Infants, GM Medical, Fukuoka, Japan) and manually ventilated it at a rate of approximately 60 times/min, according to the NCPR textbook [16]. When the bronchial pressure indicated on the built-in manometer showed elevations higher than 20 cmH2O more than six times in 10 ventilations, the attempt was considered successful. A video camera was used to record the procedure, along with the view of the manometer gauge, enabling video review in cases where the live assessment of the insertion time and success was ambiguous.

2.3. Backgrounds of Participants

We collected the background information of each participant, including specialty, years of healthcare service, previous experience using either type of neonatal supraglottic airway device, and past participation in an NCPR training course.

2.4. Data Analysis

All statistical analyses were performed using SPSS for Windows (ver. 29, IBM, Armonk, NY, USA). The primary outcome was the successful insertion of the supraglottic airway devices within an insertion time shorter than the 75th percentile of all successful attempts. The secondary outcomes were: (i) successful insertion regardless of the time spent, (ii) insertion time in all successful attempts, and (iii) successful insertion within an insertion time shorter than the 50th percentile of all successful attempts. A generalized estimating equation was used to investigate the dependence of outcomes on participants’ backgrounds by incorporating findings from repeated assessments of the same participants. Logistic regression and linear regression structures were used for the binary and continuous outcomes, respectively. A univariate analysis was performed to determine the crude effect of each independent variable. For the primary outcome, multivariate analysis was performed to clarify the dependence of successful insertion on the supraglottic airway device type, with adjustment for the specialty, career, and experience of the participants and the order of insertion. The threshold for significance was set at p < 0.05 and not corrected for multiple comparisons; however, p-values close to the threshold were interpreted cautiously. Values are shown as number (percentage), mean (standard deviation), median (quartile ranges), odds ratio (OR), and 95% confidence intervals unless otherwise noted.

3. Results

3.1. Study Population

Ninety-one nurses (n = 41), midwives (n = 15), physicians (n = 15), student nurses (n = 13), medical clerks (n = 6), and one hospital specialist participated in the study. Forty-two (46%) participants completed the NCPR training course. The number of years of healthcare service was 5 (2–11) (Table 1).

3.2. Total Successful Rate and Insertion Time

All participants successfully completed the study procedure, leaving data from 364 attempts available for analysis; no data were missing. Of the 364 insertion attempts made by the 91 participants, 200 (54.9%) were successful. The insertion time was 6.0 (10.7–16.4) s in the whole dataset and 6.5 (10.9–16.7) s when failed attempts were excluded.

3.3. Determinants of the Primary Outcome

In the univariate analysis, successful insertion < 16.4 s (75th percentile of all successful attempts) was negatively associated with the use of the Laerdal simulator (odds ratio [OR], 0.043; 05% 95% confidence interval [CI], 0.023–0.079; p < 0.001) and laryngeal mask (OR, 0.619; 95% CI, 0.464–0.825; p = 0.001) (Table 2).
In the multivariate analysis adjusted for insertion order, occupation, and clinical experience, the outcome was negatively associated with the use of the Laerdal simulator (OR, 0.034; 05% 95% CI, 0.018–0.066; p < 0.001) and laryngeal masks (OR, 0.474; 95% CI, 0.292–0.771; p = 0.003) (Table 3).

3.4. Determinants of Secondary Outcomes

When the time spent on insertion was ignored, successful insertion was negatively associated with the use of the Laerdal simulator (OR, 0.004; 95% CI, 0.002–0.011; p < 0.001) (Table 4).
When data from all successful attempts were assessed, the insertion time was associated with the duration of clinical experience (>11 years vs. 2–11 years; regression coefficient, 0.020; 95% CI, 0.001–0.602; p = 0.024) and the use of laryngeal masks (regression coefficient, 151.091; 95% CI, 11.099–2056.846; p < 0.001) (Table 5).
Successful insertion within 10.9 s (50th percentile of all successful attempts) was inversely associated with the Laerdal simulator (OR, 0.099; 95% CI, 0.054–0.182; p < 0.001) and laryngeal mask (OR, 0.196; 95% CI, 0.122–0.316; p < 0.001).

4. Discussion

Using two neonatal simulation manikins with different difficulties for supraglottic airway device insertion, we demonstrated that the i-gel was superior to the laryngeal mask, with a higher success rate within a fixed period and shorter insertion time among all successful attempts. The success rate was not associated with healthcare specialty, years of healthcare service, previous experience using supraglottic airway devices, or participation in NCPR training. These data suggest the potential advantages of using the i-gel and may justify the relevance of conducting a randomized trial comparing laryngeal masks and i-gels in neonatal resuscitation.

4.1. Comparison of Supraglottic Airway Devices in Airway Management

Since the first supraglottic airway device was proposed [6], several revised models have been created [7]. These newly developed devices are classified into those with air-inflatable cuffs and those with ergonomically preshaped cuffs. The i-gel is a relatively new and unique supraglottic airway device with a gel-filled cuff. Findings from studies comparing insertion times between these devices lack consistency. Lee et al. compared the laryngeal mask (Laryngeal Mask Classic, Laryngeal Mask Company Ltd., Henley-on-Thames, UK) and i-gel in 99 children aged 1–108 months and demonstrated that the insertion time was shorter with the i-gel than with the laryngeal mask [8]. Kayhan et al. reported similar findings in favor of i-gel versus laryngeal masks (Laryngeal Mask ProSeal, LMA North America Inc., San Diego, CA, USA) in 50 infants weighing 2–5 kg [10]. However, a randomized equivalence trial in 170 children aged 3 months to 11 years showed no difference in the insertion time between the laryngeal mask (Laryngeal Mask Supreme, LMA North America, San Diego, CA, USA) and the i-gel [9]. Another randomized study in 54 relatively smaller infants weighing <10 kg also noted no difference in the insertion time between the laryngeal mask (classic laryngeal mask) and i-gel [11]. In contrast, a study of 60 randomized pediatric patients weighing between 10 and 25 kg found that the insertion time for the laryngeal mask (Laryngeal Mask Supreme) was significantly shorter than that of the i-gel [12]. These studies investigated the performance of supraglottic airway devices using a wide age range of children during the induction of general anesthesia. However, few studies have focused on airway management during neonatal resuscitation. Using neonatal simulation manikins, our study demonstrated that using the i-gel was associated with more precise and faster airway management than the laryngeal mask, regardless of the specialty and experience of the participating healthcare providers. These findings may justify the need for a randomized clinical trial to compare the performances of laryngeal masks and i-gels in neonatal resuscitation.

4.2. Dependence of Successful Insertion on Providers’ Backgrounds

Thus far, few studies have investigated the dependence of successful supraglottic airway device insertion on the type of providers, presumably because most previous studies addressed supraglottic airway device-based airway management during general anesthesia, which is usually performed by trained anesthesiologists [8,9,10,11,12,13,14,15]. One study compared the success rates of airway management by nurse specialists, paramedics, and anesthesia residents using three different supraglottic airway devices in a neonatal simulation manikin (Ambu M-Mega Code Baby, Ambu, Hessen, Germany) [17]. This study found no significant differences in the success rates or airway management scores among the three health occupations. Our current study showed that the primary and secondary outcomes were not associated with specialty, years of healthcare service, previous experience using supraglottic airway devices, or participation in NCPR training, except that a longer duration of healthcare service showed a modest association with a shorter time to successful insertion. Our findings suggest that airway management using a laryngeal mask and i-gel is minimally influenced by the provider’s background. The printed instructions and live demonstrations by the study team staff might have been sufficient to saturate the working image of the providers required to use these supraglottic airway devices. Indeed, in studies examining the efficacy of laryngeal masks in neonatal resuscitation, only a simple additional module was used in basic and essential newborn resuscitation programs [4,18]. However, another explanation is possible. In this study, as well as with previous experience of using supraglottic airway devices and participation in the NCPR course, the order of attempts did not affect the success rate of the insertion. Furthermore, we observed a trend of decreasing success rate with an increasing number of attempts. Although the exact reason remains unclear, this may be explained by fatigue and loss of concentration resulting from multiple insertions. Airway management skills using supraglottic airway devices may be difficult to improve at a certain level. Training programs that provide extended skills for supraglottic airway device insertion are required.

4.3. Relevance of Evaluating Supraglottic Airway Devices in Simulation Manikins

This study was conducted in neonatal simulation manikins. Owing to this setting, participating providers were able to repeat insertion attempts several times, which helped highlight the dependence of successful insertion on the device type and provider’s backgrounds. To account for possible inter-neonate variations in the anatomical structure in the clinical setting, we used two different types of neonatal simulation manikins. While both manikins were designed to mimic term neonates weighing 2.5–3.5 kg and are widely used in Japanese NCPR training courses, the success rate of insertion remained at 9.9% for the Laerdal model and 72.0% for the Koken model. Several settings specific to the current study might have contributed to the relatively low success rate. First, since the Laerdal manikin is specifically designed for endotracheal intubation training, the tongue is relatively larger in size, leaving less space around the larynx compared to the Koken manikin (Figure 1). Thus, structural issues might have contributed to the lower insertion success rate, especially for the Laerdal manikin. Second, the participating providers were given only a brief instruction and demonstration before performing airway management, which might be improved with a number of appropriate practice sessions using the same devices. Third, although we used lubrication before insertion, its efficacy might differ between two SGA devices, and also between manikins and human neonates. Finally, we defined successful insertion as achieving the peak pressure of ≥20 cmH2O with a constant squeezing force of the bag provided by an experienced staff neonatologist. However, in clinical settings, the squeezing force can be adjusted in response to poor chest movement until sufficient ventilation is achieved. Therefore, the current definition of successful insertion might excessively be stringent, presumably identifying highly precise insertions of SGA devices with the minimum leakage of the air. Indeed, in a study using a neonatal manikin, failures in insertion attempt and airway management were defined as removal of the device from the mouth and a failure to achieve a successful insertion within the three attempts, respectively [19]. Another study using seven different SGA devices and a self-inflating bag in a neonatal manikin demonstrated that the mean peak inspiratory pressure of 20 cmH2O was achieved with only three devices [20]. As Micaglio et al. performed in their study of a neonatal manikin, different positive pressures may need to be applied in future studies to compare the level of oropharyngeal leak pressures between different SGA devices [21]. These fundamental differences between resuscitation simulating in future clinical studies are required to assess these findings in simulation manikins and human neonates need to be noted when interpreting our findings into clinical practice.

4.4. Limitaions

In addition to the significant difference between resuscitation manikins and human neonates, several other limitations of our study need to be considered. First, unlike most previous studies that targeted a relatively wide range of infants and children undergoing general anesthesia, our study focused on neonatal resuscitation. Subsequently, only size 1.0 laryngeal mask and i-gel were used with neonatal resuscitation manikins, rendering comparisons with other studies difficult. Considering the increasing use of supraglottic airway devices in preterm infants, including those as young as 28 weeks gestational age and with birth weights as low as 810 g [22], further research using manikins designed to mimic preterm-born neonates is warranted. Second, this study recruited providers at a single center, resulting in relatively uniform backgrounds of the participating providers, especially in terms of their skills in neonatal resuscitation. Additionally, because of the limited study population, we were not able to fully assess the influence of providers’ backgrounds to the outcome.

5. Conclusions

Our study of 91 healthcare providers suggested that for the airway management of neonatal simulator manikins, using i-gel was associated with a higher success rate within a fixed time and shorter insertion time within successful attempts than that of the laryngeal mask. Considering that the provider’s specialty, experience, and training had minimal impact on successful insertion, prospective clinical studies are warranted to investigate the potential advantage of using the i-gel for neonatal resuscitation by comparing laryngeal masks and i-gels.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/children11050530/s1, Figure S1: Instruction for LMA; Figure S2: Instruction for i-gel.

Author Contributions

Conceptualization, T.S. (Takahiro Sugiura), R.U. and O.I.; Data curation, R.U., S.F., T.S. (Tsutomu Shioda) and O.I.; Formal analysis, T.S. (Takahiro Sugiura), R.U., T.S. (Tsutomu Shioda) and O.I.; Funding acquisition, T.S. (Takahiro Sugiura) and O.I.; Investigation, T.S. (Takahiro Sugiura), R.U., T.S. (Tsutomu Shioda) and T.F.; Methodology, T.S. (Takahiro Sugiura), S.F., T.S. (Tsutomu Shioda) and O.I.; Project administration, T.S. (Takahiro Sugiura); Resources, T.S. (Takahiro Sugiura); Software, O.I.; Supervision, T.F. and O.I.; Validation, T.S. (Takahiro Sugiura), R.U. and T.S. (Tsutomu Shioda); Writing—original draft, T.S. (Takahiro Sugiura) and R.U.; Writing—review and editing, T.S. (Takahiro Sugiura), R.U., S.F., T.S. (Tsutomu Shioda), T.F. and O.I. All authors have read and agreed to the published version of the manuscript.

Funding

This study was supported by grants from the Ministry of Health, Labour, and Welfare of Japan (H24-Shinnkin-Ippan-001) and Japan Science and Technology Agency (COI-NEXT Program, JPMJPF2217).

Institutional Review Board Statement

The study protocol was approved by the Institutional Review Board of the Shizuoka Saiseikai General Hospital, Shizuoka, Japan (reference number: 20231601 on 4 March 2024).

Informed Consent Statement

Written informed consent was implied by the return of questionnaires sent to the participants who inquired about their background information.

Data Availability Statement

The data presented in this study are available on request from the corresponding author due to privacy restrictions and ethical reasons.

Acknowledgments

The authors thank all study participants.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Wyckoff, M.H.; Wyllie, J.; Aziz, K.; de Almeida, M.F.; Fabres, J.; Fawke, J.; Guinsburg, R.; Hosono, S.; Isayama, T.; Kapadia, V.S.; et al. Neonatal Life Support: 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Circulation 2020, 142 (Suppl. S1), S185–S221. [Google Scholar] [CrossRef] [PubMed]
  2. Ersdal, H.L.; Mduma, E.; Svensen, E.; Perlman, J.M. Early initiation of basic resuscitation interventions including face mask ventilation may reduce birth asphyxia related mortality in low-income countries: A prospective descriptive observational study. Resuscitation 2012, 83, 869–873. [Google Scholar] [CrossRef] [PubMed]
  3. Foglia, E.E.; Ades, A.; Sawyer, T.; Glass, K.M.; Singh, N.; Jung, P.; Quek, B.H.; Johnston, L.C.; Barry, J.; Zenge, J.; et al. Neonatal Intubation Practice and Outcomes: An International Registry Study. Pediatrics 2019, 143, e20180902. [Google Scholar] [CrossRef] [PubMed]
  4. Pejovic, N.J.; Trevisanuto, D.; Lubulwa, C.; Myrnerts Hook, S.; Cavallin, F.; Byamugisha, J.; Nankunda, J.; Tylleskär, T. Neonatal resuscitation using a laryngeal mask airway: A randomised trial in Uganda. Arch. Dis. Child. 2018, 103, 255–260. [Google Scholar] [CrossRef]
  5. Wyckoff, M.H.; Greif, R.; Morley, P.T.; Ng, K.C.; Olasveengen, T.M.; Singletary, E.M.; Soar, J.; Cheng, A.; Drennan, I.R.; Liley, H.G.; et al. 2022 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations: Summary From the Basic Life Support; Advanced Life Support; Pediatric Life Support; Neonatal Life Support; Education, Implementation, and Teams; and First Aid Task Forces. Circulation 2022, 146, e483–e557. [Google Scholar]
  6. Brain, A.I. The laryngeal mask—A new concept in airway management. Br. J. Anaesth. 1983, 55, 801–805. [Google Scholar] [CrossRef] [PubMed]
  7. van Zundert, T.C.; Brimacombe, J.R.; Ferson, D.Z.; Bacon, D.R.; Wilkinson, D.J. Archie Brain: Celebrating 30 years of development in laryngeal mask airways. Anaesthesia 2012, 67, 1375–1385. [Google Scholar] [CrossRef]
  8. Lee, J.R.; Kim, M.S.; Kim, J.T.; Byon, H.J.; Park, Y.H.; Kim, H.S.; Kim, C.S. A randomised trial comparing the i-gel (TM) with the LMA Classic (TM) in children. Anaesthesia 2012, 67, 606–611. [Google Scholar] [CrossRef]
  9. Jagannathan, N.; Sommers, K.; Sohn, L.E.; Sawardekar, A.; Shah, R.D.; Mukherji, I.I.; Miller, S.; Voronov, P.; Seraphin, S. A randomized equivalence trial comparing the i-gel and laryngeal mask airway Supreme in children. Paediatr. Anaesth. 2013, 23, 127–133. [Google Scholar] [CrossRef]
  10. Kayhan, G.E.; Begec, Z.; Sanli, M.; Gedik, E.; Durmus, M. Performance of size 1 I-gel compared with size 1 ProSeal laryngeal mask in anesthetized infants and neonates. Sci. World J. 2015, 2015, 426186. [Google Scholar] [CrossRef]
  11. Kim, M.S.; Oh, J.T.; Min, J.Y.; Lee, K.H.; Lee, J.R. A randomised comparison of the i-gel and the Laryngeal Mask Airway Classic in infants. Anaesthesia 2014, 69, 362–367. [Google Scholar] [CrossRef] [PubMed]
  12. Kus, A.; Gok, C.N.; Hosten, T.; Gurkan, Y.; Solak, M.; Toker, K. The LMA-Supreme versus the I-gel in simulated difficult airway in children: A randomised study. Eur. J. Anaesthesiol. 2014, 31, 280–284. [Google Scholar] [CrossRef] [PubMed]
  13. Oba, S.; Turk, H.S.; Kilinc, L.; Eksioglu Karaci, B.; Islamoglu, S. Comparing I-Gel to Proseal Laryngeal Mask Airways in Infants: A Prospective Randomised Clinical Study. Turk. J. Anaesthesiol. Reanim. 2020, 48, 308–313. [Google Scholar] [CrossRef] [PubMed]
  14. Sanket, B.; Ramavakoda, C.Y.; Nishtala, M.R.; Ravishankar, C.K.; Ganigara, A. Comparison of Second-Generation Supraglottic Airway Devices (i-gel versus LMA ProSeal) during Elective Surgery in Children. AANA J. 2015, 83, 275–280. [Google Scholar] [PubMed]
  15. Theiler, L.G.; Kleine-Brueggeney, M.; Luepold, B.; Stucki, F.; Seiler, S.; Urwyler, N.; Greif, R. Performance of the pediatric-sized i-gel compared with the Ambu AuraOnce laryngeal mask in anesthetized and ventilated children. Anesthesiology 2011, 115, 102–110. [Google Scholar] [CrossRef] [PubMed]
  16. The Text Book of NCPR. The Japan Society of Perinatal and Neonatal Medicine (JSPNM): Tokyo, Japan. Available online: http://www.ncpr.jp/eng/doc/Textbook_of_NCPR.pdf (accessed on 19 January 2024).
  17. Ritzka, M.; Schunk, D.; Hopf, S.; Bitzinger, D.; Graf, B.; Trabold, B. A Comparison of Three Different Supraglottic Airway Devices in Neonatal Airway Training during Resuscitation Simulation. Int. J. Anesth. Anesthesiol. 2016, 3, 044. [Google Scholar] [CrossRef]
  18. Pejovic, N.J.; Myrnerts Hook, S.; Byamugisha, J.; Alfven, T.; Lubulwa, C.; Cavallin, F.; Nankunda, J.; Ersdal, H.; Blennow, M.; Trevisanuto, D.; et al. A Randomized Trial of Laryngeal Mask Airway in Neonatal Resuscitation. N. Engl. J. Med. 2020, 383, 2138–2147. [Google Scholar] [CrossRef] [PubMed]
  19. Trevisanuto, D.; Parotto, M.; Doglioni, N.; Ori, C.; Zanardo, V.; Micaglio, M. The Supreme Laryngeal Mask Airway™ (LMA): A new neonatal supraglottic device: Comparison with Classic and ProSeal LMA in a manikin. Resuscitation 2012, 83, 97–100. [Google Scholar] [CrossRef] [PubMed]
  20. Tracy, M.B.; Priyadarshi, A.; Goel, D.; Lowe, K.; Huvanandana, J.; Hinder, M. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin? Arch. Dis. Child. Fetal Neonatal Ed. 2018, 103, F271–F276. [Google Scholar] [CrossRef]
  21. Micaglio, M.; Trevisanuto, D.; Doglioni, N.; Zanette, G.; Zanardo, V.; Ori, C. The size 1 LMA-ProSeal: Comparison with the LMA-Classic during pressure controlled ventilation in a neonatal intubation manikin. Resuscitation 2007, 72, 124–127. [Google Scholar] [CrossRef]
  22. Gallup, J.A.; Ndakor, S.M.; Pezzano, C.; Pinheiro, J.M.B. Randomized Trial of Surfactant Therapy via Laryngeal Mask Airway versus Brief Tracheal Intubation in Neonates Born Preterm. J. Pediatr. 2023, 254, 17–24.e2. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Supraglottic airway devices used and study procedure. Laryngeal mask (a), i-gel (b), Koken Neonatal Resuscitation Model LM-089 (c), Laerdal neonatal intubation trainer (d), one-page instructions for the laryngeal mask (e) and the i-gel (f) (original Japanese instructions see Supplemental Materials), and actual study procedure using two types of manikins and two different supraglottic airway devices (g).
Figure 1. Supraglottic airway devices used and study procedure. Laryngeal mask (a), i-gel (b), Koken Neonatal Resuscitation Model LM-089 (c), Laerdal neonatal intubation trainer (d), one-page instructions for the laryngeal mask (e) and the i-gel (f) (original Japanese instructions see Supplemental Materials), and actual study procedure using two types of manikins and two different supraglottic airway devices (g).
Children 11 00530 g001
Table 1. Backgrounds of participating providers.
Table 1. Backgrounds of participating providers.
Specialty *
 Nurse41 (45.1)
 Midwife15 (16.5)
 Physician15 (16.5)
 Student nurse13 (14.3)
 Medical clerk6 (6.6)
 Hospital play specialist1 (1.1)
Experience and training *
 Years of healthcare service5 (2–11)
 Participation to NCPR course168 (46.2)
Experience of using supraglottic airway devices
 i-gel 20 (5.5)
 Laryngeal mask 36 (9.9)
 Any of above40 (11.0)
Outcomes **
 Time spent in s
  All attempts11 (6–16)
  Successful insertion only11 (1–82)
Successful insertion
  Any success200 (54.9)
  Success < 16.7 s149 (40.9)
  Success < 10.9 s97 (26.6)
  Success < 6.5 s45 (12.4)
Values are from * 91 providers and ** 364 insertion attempts, shown as number (%) or median (quartile range). Abbreviation: NCPR, Neonatal Cardio-Pulmonary Resuscitation.
Table 2. Determinants of successful insertion within 16.7 s (univariable analysis).
Table 2. Determinants of successful insertion within 16.7 s (univariable analysis).
Success < 16.7 sOdds Ratiop
VariablesYes
(n = 149)
No
(n = 215)
Mean95% Confidence Interval
LowerUpper
Insertion order
 First42 (46.2%)49 (53.8%)Reference
 Second40 (44.0%)51 (56.0%)0.9150.5211.6080.758
 Third36 (39.6%)55 (60.4%)0.7640.4261.3690.365
 Fourth31 (34.1%)60 (65.9%)0.6030.3091.1750.137
Specialty
 Physician24 (40.0%)36 (60.0%)0.9550.6191.4710.834
 Other125 (41.1%)179 (58.9%)Reference
Years of healthcare service
 ≤236 (39.1%)56 (60.9%)1.0230.6561.5950.920
 2–1171 (38.6%)113 (61.4%)Reference
 >1142 (47.7%)46 (52.2%)1.4530.9312.2670.100
Participation to Neonatal Cardio-Pulmonary Resuscitation course
 Yes70 (41.7%)98 (58.3%)1.0580.7241.5460.771
 No79 (40.3%)117 (60.0%)Reference
Experience of using i-gel
 Yes8 (40.0%)12 (60.0%)0.960.5881.5660.870
 No141 (41.0%)203 (59.0%)Reference
Experience of using laryngeal mask
 Yes15 (41.7%)21 (58.3%)1.0340.5322.0090.921
 No134 (40.9%)194 (59.1%)Reference
Experience of using i-gel or laryngeal mask
 Yes17 (42.5%)23 (57.5%)1.0750.5871.9690.815
 No132 (40.7%)192 (59.3%)Reference
Simulation manikin
 Laerdal18 (9.9%)164 (90.1%)0.0430.0230.079<0.001
 Koken131 (72.0%)51 (28.0%)Reference
Type of supraglottic airway device
 Laryngeal mask64 (35.2%)118 (64.8%)0.6190.4640.8250.001
 i-gel85 (46.7%)97 (53.3%)Reference
Table 3. Determinants of successful insertion within 16.7 s (multivariable analysis).
Table 3. Determinants of successful insertion within 16.7 s (multivariable analysis).
Odds Ratiop
VariablesMean95% Confidence Interval
LowerUpper
Insertion order
 FirstReference
 Second0.6250.2871.3590.236
 Third0.5450.2581.1510.112
 Fourth0.4340.1920.9820.045
Specialty
 Physician (vs. Othres)0.8430.242.9630.790
Years of healthcare service
 ≤21.0650.4582.4750.884
 2–11Reference
 >112.0030.9084.4180.085
Experience of using supraglottic airway device
 Yes (vs. No)1.3120.2836.080.728
Simulation manikin
 Laerdal (vs. Koken)0.0340.0180.066<0.001
Type of supraglottic airway device
 Laryngeal mask (vs. i-gel)0.4740.2920.7710.003
Table 4. Determinants of successful insertion (univariable analysis).
Table 4. Determinants of successful insertion (univariable analysis).
Odds Ratiop
VariablesYes
(n = 200)
No
(n = 164)
Mean95% Confidence Interval
LowerUpper
Insertion order
 First52 (57.1%)39 (42.9%)Reference
 Second53 (58.2%)38 (41.8%)1.0460.5571.9640.889
 Third50 (54.9%)41 (45.0%)0.9150.4931.6970.777
 Fourth45 (49.5%)46 (50.5%)0.7340.3771.4280.362
Specialty
 Physician30 (50.0%)30 (50.0%)0.7880.6240.9950.046
 Other170 (55.9%)134 (44.1%)Reference
Years of healthcare service
 ≤2 49 (53.3%)43 (46.7%)0.8960.6771.1870.444
 2–11103 (56.0%)81 (44.0%)Reference
 >1148 (54.5%)40 (45.5%)0.9440.6821.3060.726
Participation to NCPR course
 Yes92 (54.8%)76 (45.2%)0.9860.771.2640.913
 No108 (55.1%)88 (44.9%)Reference
Experience of using i-gel
 Yes10 (50.0%)10 (50.0%)0.8110.7110.9240.002
 No190 (55.2%)154 (44.8%)Reference
Experience of using laryngeal mask
 Yes21 (58.3%)15 (41.7%)1.1650.7311.8570.520
 No179 (54.6%)149 (45.4%)Reference
Experience of using i-gel or laryngeal mask
 Yes23 (57.5%)17 (42.5%)1.1240.7341.7210.592
 No177 (54.6%)147 (45.4%)Reference
Simulation manikin
 Laerdal23 (12.6%)159 (87.4%)0.0040.0020.011<0.001
 Koken177 (97.3%)5 (2.7%)Reference
Type of supraglottic airway device
 Laryngeal mask99 (54.4%)83 (45.6%)0.9570.7881.1620.655
 i-gel101 (55.5%)81 (44.5%)Reference
Table 5. Determinants of time spent for successful insertion (univariable analysis).
Table 5. Determinants of time spent for successful insertion (univariable analysis).
Time (s)Regression Coefficientp
VariablesMean (Standard Deviation)Mean95% Confidence Interval
LowerUpper
Insertion order
 First12.4 (13.3)Reference
 Second14.8 (11.8)2.448−2.2327.1290.305
 Third14.2 (11.1)1.821−3.0126.6540.46
 Fourth13.3 (9.0)0.897−3.4755.270.687
Specialty
 Physician13.2 (13.8)−0.645−6.1594.8690.819
 Other13.8 (11.0)Reference
Years of healthcare service
 ≤213.4 (13.6)−1.64−6.4813.2010.507
 2–1115.0 (11.5)Reference
 >1111.1 (8.3)−3.918−7.329−0.5080.024
Participation to Neonatal Cardio-Pulmonary Resuscitation course
 Yes13.5 (10.6)−0.461−3.9263.0040.794
 No13.9 (12.1)Reference
Experience of using i-gel
 Yes12.9 (3.9)−0.855−4.1332.4230.609
 No13.7 (11.7)Reference
Experience of using laryngeal mask
 Yes13.0 (9.8)−0.746−5.2363.7450.745
 No13.8 (11.6)Reference
Experience of using i-gel or laryngeal mask
 Yes13.0 (9.3)−0.823−5.0053.3590.700
 No13.8 (11.7)Reference
Simulation manikin
 Laerdal11.0 (7.1)−3.092−6.5840.4000.083
 Koken14.1 (11.8)Reference
Type of supraglottic airway device
 Laryngeal mask16.2 (8.5)5.0182.4077.629<0.001
 i-gel11.2 (13.3)Reference
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Sugiura, T.; Urushibata, R.; Fukaya, S.; Shioda, T.; Fukuoka, T.; Iwata, O. Dependence of Successful Airway Management in Neonatal Simulation Manikins on the Type of Supraglottic Airway Device and Providers’ Backgrounds. Children 2024, 11, 530. https://doi.org/10.3390/children11050530

AMA Style

Sugiura T, Urushibata R, Fukaya S, Shioda T, Fukuoka T, Iwata O. Dependence of Successful Airway Management in Neonatal Simulation Manikins on the Type of Supraglottic Airway Device and Providers’ Backgrounds. Children. 2024; 11(5):530. https://doi.org/10.3390/children11050530

Chicago/Turabian Style

Sugiura, Takahiro, Rei Urushibata, Satoko Fukaya, Tsutomu Shioda, Tetsuya Fukuoka, and Osuke Iwata. 2024. "Dependence of Successful Airway Management in Neonatal Simulation Manikins on the Type of Supraglottic Airway Device and Providers’ Backgrounds" Children 11, no. 5: 530. https://doi.org/10.3390/children11050530

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop