Next Article in Journal
Potential of Porous Substrate Bioreactors for Removal of Pollutants from Wastewater Using Microalgae
Next Article in Special Issue
Design Optimization and Tradeoff Analysis of an Actuated Continuum Probe for Pulmonary Nodule Localization and Resection
Previous Article in Journal
PosturAll: A Posture Assessment Software for Children
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Individualized PEEP without Recruitment Maneuvers Improves Intraoperative Oxygenation: A Randomized Controlled Study

1
Department of Anesthesiology, Fudan University Shanghai Cancer Center, Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, China
2
School of Biomedical Engineering, Guangzhou Medical University, Guangzhou 511436, China
3
Institute of Technical Medicine, Furtwangen University, 78054 Villingen-Schwenningen, Germany
*
Authors to whom correspondence should be addressed.
These authors contributed equally to this work.
Bioengineering 2023, 10(10), 1172; https://doi.org/10.3390/bioengineering10101172
Submission received: 30 July 2023 / Revised: 25 September 2023 / Accepted: 26 September 2023 / Published: 9 October 2023
(This article belongs to the Special Issue Visual Image Technologies for Respiratory and Circulatory Management)

Abstract

:
Individualized positive end-expiratory pressure (PEEP) combined with recruitment maneuvers improves intraoperative oxygenation in individuals undergoing robot-assisted prostatectomy. However, whether electrical impedance tomography (EIT)-guided individualized PEEP without recruitment maneuvers can also improve intraoperative oxygenation is unknown. To test this, fifty-six male patients undergoing elective robot-assisted laparoscopic prostatectomy were randomly assigned to either individualized PEEP (Group PEEPIND, n = 28) or a control with a fixed PEEP of 5 cm H2O (Group PEEP5, n = 28). Individualized PEEP was guided by EIT after placing the patients in the Trendelenburg position and performing intraperitoneal insufflation. Patients in Group PEEPIND maintained individualized PEEP without intermittent recruitment maneuvers, and those in Group PEEP5 maintained a PEEP of 5 cm H2O intraoperatively. Both groups were extubated in a semi-sitting position once the extubation criteria were met. The primary outcome was arterial oxygen partial pressure (PaO2)/inspiratory oxygen fraction (FiO2) prior to extubation. Other outcomes included intraoperative driving pressure, plateau pressure and dynamic, respiratory system compliance, and the incidence of postoperative hypoxemia in the post-operative care unit (PACU). Our results showed that the intraoperative median for PEEPIND was 16 cm H2O (ranging from 12 to 18 cm H2O). EIT-guided PEEPIND was associated with higher PaO2/FiO2 before extubation compared to PEEP5 (71.6 ± 10.7 vs. 56.8 ± 14.1 kPa, p = 0.003). Improved oxygenation extended into the PACU with a lower incidence of postoperative hypoxemia (3.8% vs. 26.9%, p = 0.021). Additionally, PEEPIND was associated with lower driving pressures (12.0 ± 3.0 vs. 15.0 ± 4.4 cm H2O, p = 0.044) and better compliance (44.5 ± 12.8 vs. 33.6 ± 9.1 mL/cm H2O, p = 0.017). Our data indicated that individualized PEEP guided by EIT without intraoperative recruitment maneuvers also improved perioperative oxygenation in patients undergoing robot-assisted laparoscopic radical prostatectomy, which could benefit patients with the risk of intraoperative hemodynamic instability caused by recruitment maneuvers. Trial registration: China Clinical Trial Registration Center Identifier: ChiCTR2100053839. This study was registered on 1 December 2021. The first patient was recruited on 15 December 2021.

1. Introduction

Robot-assisted laparoscopic radical prostatectomy is associated with high abdominal pressure and requires an extreme Trendelenburg position for optimal surgical access [1]. During general anesthesia, these two factors combined with lung ventilation shifting toward ventral regions promote pulmonary atelectasis, which can contribute to postoperative pulmonary complications [2]. Because of a patient’s individual constitution, body mass index (BMI), positioning, and intra-abdominal pressure, the individual positive end-expiratory pressure (PEEP) setting during intraoperative mechanical ventilation is recommended to counteract these effects [3,4,5]. The individual PEEP setting during general anesthesia has been reported to reduce intrapulmonary shunt and postoperative pulmonary complications in elderly patients undergoing spinal surgery in the prone position [6].
Several techniques have been used to determine individual PEEP, also known as optimal PEEP [7,8,9]. Chest computer tomography (CT) is the gold standard technique for the assessment of lung inflation and atelectasis [10]. However, it exposes individuals to radiation and is not feasible for bedside use. The measurement of transpulmonary pressure is another alternative that can be used at the bedside, although it requires special training and additional equipment in order to obtain transpulmonary pressure [11]. However, this method is not practical for evaluating regional lung ventilation distribution. Electrical impedance tomography (EIT) has been demonstrated to individualize the PEEP level [12,13], which minimizes atelectasis and prevents lung overdistension [14,15]. Individual PEEP guided by EIT and combined with recruitment maneuvers improves intraoperative oxygenation, compared with standard ventilation with PEEP of 5 cm H2O, both in morbidly obese and normal patients undergoing laparoscopic surgery [4,16]. However, recruitment maneuvers may cause intraoperative hemodynamic instability [4,17] and intermittent manual operations are inconvenient.
Therefore, we tested the hypothesis that EIT-guided individualized PEEP without recruitment maneuvers also improves intraoperative oxygenation, when compared to 5 cm H2O PEEP in patients undergoing robot-assisted laparoscopic radical prostatectomy.

2. Materials and Methods

2.1. Ethics Approval

This prospective, randomized, controlled, single-center study was approved by the ethics committee of Fudan University Shanghai Cancer Center (number: IRB2010225-11) and registered with the China Clinical Trial Registration Center (ChiCTR2100053839). The first patient was recruited on 15/12/2021 by the Fudan University Shanghai Cancer Center. Informed consent was obtained from every patient before enrollment. An investigator assessed patients for eligibility the day before surgery.

2.2. Inclusion Criteria

  • Patients undergoing elective robot-assisted prostate surgery under general anesthesia;
  • American Society of Anesthesiologists (ASA) grade I~III;
  • BMI < 30 kg/m2.

2.3. Exclusion Criteria

  • Untreated ischemic heart disease;
  • Acute or chronic respiratory failure and moderate to severe obstructive or restrictive pulmonary diseases, including chronic obstructive pulmonary disease and asthma;
  • Previous lung or airway surgery;
  • Neuromuscular diseases;
  • Preoperative SpO2 (in room air) < 95%.

2.4. Anesthesia Management

The demographic data and clinical characteristics were recorded after patients entered the operating room. Standard monitoring protocols were applied, including ECG, pulse oximetry, and capnography. Intravenous access was established, and a radial arterial line was established for invasive blood pressure monitoring and arterial blood gas (ABG) analysis. Pre-oxygenation was performed for 3 min (oxygen concentration: 100%, oxygen flow: 6 L/min) before anesthesia. The anesthetic induction was conducted with an intravenous-targeted control infusion (TCI) of propofol (Marsh mode) at 4 μg/mL, sufentanil at 0.3 μg/kg, remifentanil (Minto mode) at 2 ng/mL, and rocuronium at 0.6 mg/kg. A 7.0-size tracheal tube was inserted, and correct placement was confirmed through auscultation and the presence of bilateral equal breath sounds. General anesthesia was maintained with the continuous TCI infusion of propofol 3–4 μg/mL and remifentanil 1–2 ng/mL, as well as the intermittent administration of rocuronium in order to maintain adequate muscle paralysis.

2.5. Intraoperative Ventilation

After tracheal intubation, patients were provided with pressure-regulated volume-controlled ventilation (Flow-I, Maquet Inc., Heidelberg, Germany). The ventilation was set at a tidal volume of 6–8 mL/kg predicted body weight (PBW), FiO2 = 0.5, PEEP = 18 cm H2O in the PEEPIND Group (before individual PEEP titration), and a respiratory rate of 12–15 beats/min was set to maintain the end-tidal CO2 partial pressure between 35 and 45 mmHg.

2.6. Measurements

Demographic data and medical characteristics, including sex, age, BMI, PBW, ASA classification, medical history, invasive blood pressure, and heart rate, were collected. Intraoperative tidal volume, dynamic respiratory system compliance (Cdyn), driving pressure, plateau pressure, and ABG at 5 and 60 min after an individual or fixed PEEP setting and before extubation were recorded. The ABG analysis (GEM3500; Instrumentation Laboratory, USA) was performed simultaneously. We collected regional lung ventilation distribution before anesthetic induction (T0) 5 and 60 min after the PEEP setting (T1, T2) and 10 min after extubation (T3).
EIT data were obtained using a commercial EIT system (PulmoVista500; Draeger Medical, Luebeck, Germany) after PEEP levels had been set in both groups. In the present study, an EIT electrode belt, which carries 16 electrodes with a width of 40 mm, was placed around the thorax in the fifth intercostal space, and a reference electrode was placed on the right thorax.

2.7. The Individual PEEP Titration by EIT

All patients were placed in a steep 30-degrees Trendelenburg position prior to incision. Abdominal access, insufflation, and docking of the robot occurred at a pneumoperitoneum pressure of 14 mmHg. All cases were completed using the DavinciTM Xi Robot and AirSealTM iFS device (Intuitive Surgical, Inc., Sunnyvale, CA, USA). The individual PEEP titration with EIT in the PEEPIND Group started after the patient’s placement in the Trendelenburg position and peritoneal insufflation (Supplementary Figure S1). PEEP started at 18 cm H2O and decreased by 2 cm H2O each time for 2 min until 8 cm H2O was reached. Then, the optimal PEEP value was defined as the intercept of cumulated collapse and overdistension percentage curves to minimize regional compliance loss [18] using customized software [19]. After individual PEEP titration, patients in the PEEPIND Group were maintained at their individual PEEP level until extubation; by contrast, those in the PEEP5 Group were maintained at a fixed PEEP level (5 cm H2O) until extubation. There were no intermittent recruitment maneuvers in either group.

2.8. Outcome Measures

The primary outcome in the present study was PaO2/FiO2 before extubation. Other outcome parameters included:
(1)
Intraoperative driving pressure, plateau pressure, and Cdyn;
(2)
Ventral over dorsal ventilation distribution ratio;
(3)
Intraoperative hemodynamics;
(4)
The incidence of postoperative hypoxemia (SpO2 < 92% were on room air after extubation) in the PACU.

2.9. Statistical Analysis

Intraoperative PaO2/FiO2 was reported as 55.7 ± 10.8 kPa before extubation in patients undergoing robot-assisted laparoscopic prostatectomy [4]. We assumed that there was a 9 kPa difference between the two groups, with a variance of 10.8 kPa, a statistical power of 80%, and a two-sided α significance level of 0.05; therefore, at least 23 patients in each group did not need to be recruited. Considering a dropout rate of 20%, a total of 29 patients for each group (for a total of 58 patients) were enrolled. A minimization randomization method was performed via MinimPy2 software (version 2.0, OSDN, Columbus, OH, USA). SPSS 20.0 software was used for statistical analysis. Measurement data were expressed as mean ± standard deviation or median (interquartile range) where appropriate. The Chi-square test and Fisher’s exact test were used for categorical variables, and the t-test or Mann–Whitney U test were used for continuous variables. The differences were considered statistically significant when p < 0.05.

3. Results

A total of 58 patients were initially enrolled in the study period. Fifty-six patients were randomized (Figure 1). Finally, 52 patients were included in the final analysis, 26 in each group. Their clinical characteristics are listed in Table 1.
The mean individualized PEEP guided by EIT in the PEEPIND Group was 16 cm H2O (ranging from 12 to 18 cm H2O).
PaO2/FiO2 in the PEEPIND Group was 14.8 kPa higher than the PEEP5 Group before extubation (71.6 ± 10.7 vs. 56.8 ± 14.1 kPa, p = 0.003, Table 2).
Before extubation, the individualized PEEP level guided by EIT was associated with higher plateau pressure when compared to the 5 cm H2O PEEP setting (27.5 ± 3.4 cm H2O vs. 20.0 ± 4.4 cm H2O, p < 0.001), resulting in significantly lower driving pressures (12.0 ± 3.0 cm H2O vs. 15.0 ± 4.4 cm H2O, p = 0.044) and better Cdyn (44.5 ± 12.8 cm H2O vs. 33.6 ± 9.1 cm H2O, p = 0.017). The results are shown in Table 2. The power test of the driving pressure was 0.94, plateau pressure was 1, and Cdyn was 0.99.
The hemodynamic parameters, such as heart rate, blood pressure, doses of vasopressor, and fluid infusions, during mechanical ventilation were similar between the two groups (Table 1 and Table 2).
Further analysis indicated that individualized PEEP guided by EIT was associated with improved regional lung ventilation distribution when compared with 5 cm H2O PEEP during mechanical ventilation (Table 3), which resulted in improved oxygenation immediately after extubation and a lower incidence of postoperative hypoxemia in the PACU (3.8% vs. 26.9%, p = 0.021, Table 4).

4. Discussion

In the present study, we found that maintaining the individualized PEEP level guided by EIT without recruitment maneuvers improved intraoperative oxygenation. The benefit of intraoperative individualized PEEP could extend into the postoperative period after extubation, as evidenced by an increase in PaO2/FiO2 and a decrease in the incidence of postoperative hypoxemia in PACU when compared with a fixed PEEP setting.
We tested our hypothesis on patients who underwent robot-assisted laparoscopic radical prostatectomy. Robot-assisted radical prostatectomy can be performed via either transperitoneal or total extra-peritoneal approaches. Transperitoneal robot-assisted radical prostatectomy, the most frequently used approach worldwide, has the advantages of a wider working space, a shorter duration for trocar positioning and preparing the workspace, and meticulous lymph node dissection [20,21,22]. The disadvantages of transperitoneal robot-assisted radical prostatectomy are associated with a higher risk of bowel injury, contraindications for obesity or intraperitoneal adhesions, and Trendelenburg positioning at nearly 35–40 degrees [20,21,22]. However, with no contact with the bowel and less inclined patient positioning (15–20 degrees), extra-peritoneal robot-assisted radical prostatectomy has the technical disadvantages of a narrower working space, more time spent on preparing the extraperitoneal field, and the lack of a combined approach to the bladder anteriorly and posteriorly [20,21]. In addition, extra-peritoneal robot-assisted radical prostatectomy is associated with higher partial CO2 pressure, causing a subsequent decrease in arterial pH [21]. In our medical center, robot-assisted radical prostatectomy is commonly performed via transperitoneal approaches.
High degrees of Trendelenburg positioning may cause peripheral nerve injuries [23,24] and increase the airway pressure, causing pneumothorax. Fortunately, no pneumothorax occurred in our study. The reasons for this may be that relatively low degrees of the Trendelenburg position (approximately 30 degrees in our study) were used, and patients with previous respiratory diseases were excluded. In addition, different degrees of the Trendelenburg position might lead to different individual PEEPs measured using EIT. Therefore, we used the same degree of the Trendelenburg position in the two study groups to avoid any confounding effects on body position.
The use of pneumoperitoneum is needed during robot-assisted radical prostatectomies, although it is a known risk given the change in physiological parameters that accompany its utilization. Conventionally, 15 mmHg is used in robot-assisted radical prostatectomy. However, it has also been reported that decreasing insufflation pressures from 15 to 12 mmHg can decrease the length of stay and postoperative ileus rates [25]. We used 14 mmHg pneumoperitoneum in our study.
The Trendelenburg position and high abdominal pressure may impede mechanical ventilation, leading to perioperative atelectasis in laparoscopic surgeries. Previous studies have demonstrated that using individualized PEEP combined with intermittent recruitment maneuvers for laparoscopic surgeries can counteract atelectasis formation and improve oxygenation [14]. The individualized PEEP identified by EIT has the substantial advantage of being used at the bedside [26,27]. The individualized PEEP titration process could be influenced by surgical maneuvers; therefore, in order to avoid this influence in the present study, surgeons were asked to suspend their surgical procedures during PEEP titration. The duration of PEEP titration was about 30 min. Since the surgical robot needed some time to prepare after patients had been placed in the Trendelenburg position, the actual time that it cost surgeons waiting to perform the operation was limited (5–10 min at most).
Intermittent recruitment maneuvers were not combined with individualized PEEP in our study. Girrbach et al. applied recruitment maneuvers and individualized PEEP to significantly improve intraoperative oxygenation [4]. However, hemodynamic instability is one of the concerns during recruitment maneuvers [17]. Since most cardiovascular complications, such as bradycardia and hypotension, occur during recruitment maneuvers, the majority of patients require vasopressor support to maintain normal blood pressure. Without this intermittent recruitment maneuver, medics may worry that using the same PEEP setting during the operation could lead to lung collapse. Interestingly, our results demonstrate that individualized PEEP without recruitment maneuvers also improves intraoperative oxygenation. Futier et al. compared PEEP alone and PEEP combined with recruitment maneuvers in normal weight and obese patients, respectively, undergoing laparoscopic surgery, and the results showed that 10 cm of H2O PEEP without recruitment maneuvers did not improve oxygenation, while the addition of a recruitment maneuver increased lung elastane and oxygenation [28]. Further, intraoperative-fixed PEEP level may lead to either lung overinflation or atelectasis [29]. The individualized PEEP level could improve respiratory outcomes better than fixed PEEP without increasing lung complications [4,30,31,32]. This could explain the discrepancy between the findings of Futier et al. and our own results. Shono et al. showed that high PEEP (15 cm H2O) can be associated with higher lung ventilation and oxygenation in prostate patients undergoing robot-assisted endoscopic procedures with their heads below 25° [33]. At the end of the operation, a moderate PEEP level without lung recruitment maneuvers was sufficient to achieve substantial lung opening. Our study’s findings may benefit patients with a risk of intraoperative hemodynamic instability. It also indicates that recruitment maneuvers may be unnecessary to improve oxygenation.
Our data show that a high incidence of postoperative hypoxemia (26.9% in the control group) was found after robot-assisted prostatectomy, which extended the PACU stay and increased costs. With the implementation of EIT-guided PEEP titration, PaO2/FiO2 was 14.8 kPa higher than the control group before extubation (71.6 ± 10.7 vs. 56.8 ± 14.1 kPa, p = 0.003, Table 2). The improved oxygenation extended into the PACU, as evidenced by a lower incidence of postoperative hypoxemia (3.8% vs. 26.9%, p = 0.021). Additionally, EIT-guided PEEP titration was associated with lower driving pressures and better compliance. These improvements could be explained by the distribution of local lung ventilation. These results indicate that postoperative pulmonary complications can be improved in such patients, and prognosis might also be improved. Though we did not follow up with postoperative pulmonary complications, the feasibility and advantages of using EIT in individualized PEEP titration undergoing robot-assisted prostatectomy were demonstrated.
High-level PEEP may aggravate hemodynamic instability, especially in critically ill patients [34,35]. However, there were no significant differences between the vasopressor doses used in both groups in our study, indicating that individualized PEEP guided by EIT might not significantly influence hemodynamics, which is consistent with a previous study [31]. Our results demonstrate that the benefits of intraoperative individual PEEP are sustained immediately after surgery, which is consistent with a previous study in which intraoperative individualized PEEP reduces postoperative atelectasis [36]. However, whether intraoperative PEEP improves postoperative oxygenation is controversial. Several studies have also reported that intraoperative PEEP only improved intraoperative oxygenation and failed to maintain its effect into the postoperative period [4,16]. This discrepancy may be due to different extubation approaches in different surgery centers. In our hospital, it is a routine practice to perform tracheal extubation in a semi-sitting position, which is associated with better functional residual capacity in comparison to the supine position. However, this notion requires further validation.
Our results suggest that improved regional lung ventilation distribution, as evidenced by a better ventral/dorsal distribution ratio, might contribute to improved perioperative oxygenation using EIT-guided individualized PEEP. The ventral/dorsal distribution ratio was calculated based on the percentage of tidal variation in regions of interest, and it was easily calculated by bedside personnel [37]. Patients under mechanical ventilation are usually associated with shunts due to alveolar collapse in the dorsal lung (as shown by the ventral/dorsal ratio increases, Table 3). Alveolar collapse is usually accompanied by an intrapulmonary shunt, resulting in impaired pulmonary gas exchange [38]. The significant effect of lung volume reduction on pulmonary dynamics promotes the development of atelectasis [39].
The application of EIT technology requires specialized training, and the equipment is expensive, which may require the consideration of its cost-effectiveness. However, our results show that EIT technology can improve intraoperative oxygen and decrease the incidence of postoperative hypoxemia, which may shorten patients’ hospital stays and decrease postoperative comorbidity. The EIT examination itself generates almost no cost (i.e., no consumables and low maintenance cost). The overall cost-effectiveness could be in favor of applying EIT-guided PEEP, especially for high-risk patients prone to lung atelectasis.
There are several limitations to this study. Firstly, individualized PEEP guided by EIT limited the regions of overdistension and collapse, which might not be the “optimal” PEEP in other aspects, e.g., transpulmonary pressure. The individualized PEEP titration ranged from 18 cm H2O to 8 cm H2O. If optimal PEEP was outside this range, which would be rare, our method would not be able to find it. Nevertheless, the PEEP values achieved in our study resulted in better perioperative oxygenation. However, since the sample size was small, the effect of individualized PEEP on postoperative pulmonary complications, such as atelectasis and pneumonia, was not determined in the present study.

5. Conclusions

Compared with a fixed PEEP level, the individualized PEEP level achieved using EIT without recruitment maneuvers could also improve perioperative oxygenation in patients undergoing robot-assisted laparoscopic radical prostatectomy, which may benefit patients at risk of intraoperative hemodynamic instability caused by recruitment maneuvers. However, whether this individualized PEEP without intermittent recruitment maneuvers can reduce the incidence of postoperative pulmonary complications should be further studied.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/bioengineering10101172/s1, Figure S1: Experimental protocol and interventions.

Author Contributions

L.P., L.Y. and L.G. carried out the trial procedures, analysed the data and drafted the manuscript. Z.Z. and J.Z. conceived the study, and participated in its design and coordination and helped to draft the manuscript. All authors have read and agreed to the published version of the manuscript.

Funding

Grant from Shanghai Municipal Science and Technology Committee (to Jun Zhang, No. 20Y11906200).

Institutional Review Board Statement

This study was approved by the ethics committee of Fudan University Shanghai Cancer Center (number: IRB2010225-11) and registered in the China Clinical Trial Registration Center (ChiCTR2100053839). All methods were carried out in accordance with relevant guidelines and regulations.

Informed Consent Statement

Informed consent was obtained from every patient before enrollment.

Data Availability Statement

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Acknowledgments

The authors would also like to thank urologists from the Fudan University Shanghai Cancer Center for their help and support on this project.

Conflicts of Interest

Zhanqi Zhao receives a consulting fee from Dräger Medical. Other authors declare that they have no competing interests.

References

  1. Stolzenburg, J.; Kallidonis, P.; Qazi, H.; Ho Thi, P.; Dietel, A.; Liatsikos, E.N.; Do, M. Extraperitoneal approach for robotic-assisted simple prostatectomy. Urology 2014, 84, 1099–1105. [Google Scholar] [PubMed]
  2. Andersson, L.E.; Beth, M.; Thorne, A.; Aspelin, P.; Odeberg-Wernerman, S. Effect of carbon dioxide pneumoperitoneum on development of atelectasis during anesthesia, examined by spiral computed tomography. Anesthesiology 2005, 102, 293–299. [Google Scholar] [PubMed]
  3. Sahetya, S.K. Searching for the optimal positive end-expiratory pressure for lung protective ventilation. Curr. Opin. Crit. Care 2020, 26, 53–58. [Google Scholar]
  4. Girrbach, F.; Petroff, D.; Schulz, S.; Hempel, G.; Lange, M.; Klotz, C.; Scherz, S.; Giannella-Neto, A.; Beda, A.; Jardim-Neto, A.; et al. Individualised positive end-expiratory pressure guided by electrical impedance tomography for robot-assisted laparoscopic radical prostatectomy: A prospective, randomised controlled clinical trial. Br. J. Anaesth. 2020, 125, 373–382. [Google Scholar] [PubMed]
  5. Pelosi, P.; Croci, M.; Ravagnan, I.; Tredici, S.; Pedoto, A.; Lissoni, A.; Gattinoni, L. The effects of body mass on lung volumes, respiratory mechanics, and gas exchange during general anesthesia. Anesth. Analg. 1998, 87, 654–660. [Google Scholar]
  6. Qian, M.; Yang, F.; Zhao, L.; Shen, J.; Xie, Y. Individualized positive end-expiratory pressure titration on respiration and circulation in elderly patients undergoing spinal surgery in prone position under general anesthesia. Am. J. Transl. Res. 2021, 13, 13835–13844. [Google Scholar]
  7. Maisch, S.; Reissmann, H.; Fuellekrug, B.; Weismann, D.; Rutkowski, T.; Tusman, G.; Bohm, S.H. Compliance and dead space fraction indicate an optimal level of positive End-Expiratory pressure after recruitment in anesthetized patients. Anesth. Analg. 2008, 106, 175–181. [Google Scholar]
  8. Blankman, P.; Shono, A.; Hermans, B.J.M.; Wesselius, T.; Hasan, D.; Gommers, D. Detection of optimal PEEP for equal distribution of tidal volume by volumetric capnography and electrical impedance tomography during decreasing levels of PEEP in post cardiac-surgery patients. Br. J. Anaesth. 2016, 116, 862–869. [Google Scholar]
  9. Bian, W.; Chen, W.; Chao, Y.; Wang, L.; Li, L.; Guan, J.; Zang, X.; Zhen, J.; Sheng, B.; Zhu, X. Application of dead space fraction to titrate optimal positive end-expiratory pressure in an ARDS swine model. Exp. Ther. Med. 2017, 13, 1572–1577. [Google Scholar]
  10. Malbouisson, L.M.; Muller, J.; Constantin, J.; Lu, Q.; Puybasset, L.; Rouby, J.; Ct, S.A.S.G.; The, C.S.A.S. Computed tomography assessment of positive end-expiratory pressure-induced alveolar recruitment in patients with acute respiratory distress syndrome. Am. J. Resp. Crit. Care 2001, 163, 1444–1450. [Google Scholar]
  11. Beitler, J.R.; Sarge, T.; Banner-Goodspeed, V.M.; Gong, M.N.; Cook, D.; Novack, V.; Loring, S.H.; Talmor, D.; Epvent-, S.G. Effect of titrating positive End-Expiratory pressure (PEEP) with an esophageal pressure–guided strategy vs an empirical high PEEP-Fio2 strategy on death and days free from mechanical ventilation among patients with acute respiratory distress syndrome: A randomized clinical trial. JAMA 2019, 321, 846–857. [Google Scholar] [PubMed]
  12. Hsu, H.J.; Chang, H.T.; Zhao, Z.; Wang, P.H.; Zhang, J.H.; Chen, Y.S.; Frerichs, I.; Moller, K.; Fu, F.; Hsu, H.S.; et al. Positive end-expiratory pressure titration with electrical impedance tomography and pressure-volume curve: A randomized trial in moderate to severe ARDS. Physiol. Meas. 2021, 42, 14002. [Google Scholar]
  13. Zhao, Z.; Chen, T.F.; Teng, H.C.; Wang, Y.C.; Chang, M.Y.; Chang, H.T.; Frerichs, I.; Fu, F.; Moller, K. Is there a need for individualized adjustment of electrode belt position during EIT-guided titration of positive end-expiratory pressure? Physiol. Meas. 2022, 43, 064001. [Google Scholar]
  14. Pereira, S.M.; Tucci, M.R.; Morais, C.C.A.; Simões, C.M.; Tonelotto, B.F.F.; Pompeo, M.S.; Kay, F.U.; Pelosi, P.; Vieira, J.E.; Amato, M.B.P. Individual positive end-expiratory pressure settings optimize intraoperative mechanical ventilation and reduce postoperative atelectasis. Anesthesiology 2018, 129, 1070–1081. [Google Scholar]
  15. Reinius, H.; Borges, J.B.; Engstrom, J.; Ahlgren, O.; Lennmyr, F.; Larsson, A.; Freden, F. Optimal PEEP during one-lung ventilation with capnothorax: An experimental study. Acta Anaesthesiol. Scand. 2019, 63, 222–231. [Google Scholar] [PubMed]
  16. Nestler, C.; Simon, P.; Petroff, D.; Hammermüller, S.; Kamrath, D.; Wolf, S.; Dietrich, A.; Camilo, L.M.; Beda, A.; Carvalho, A.R.; et al. Individualized positive end-expiratory pressure in obese patients during general anaesthesia: A randomized controlled clinical trial using electrical impedance tomography. Br. J. Anaesth. 2017, 119, 1194–1205. [Google Scholar] [PubMed]
  17. Suzumura, E.A.; Figueiró, M.; Normilio-Silva, K.; Laranjeira, L.; Oliveira, C.; Buehler, A.M.; Bugano, D.; Passos Amato, M.B.; Ribeiro Carvalho, C.R.; Berwanger, O.; et al. Effects of alveolar recruitment maneuvers on clinical outcomes in patients with acute respiratory distress syndrome: A systematic review and meta-analysis. Intensive Care Med. 2014, 40, 1227–1240. [Google Scholar] [PubMed]
  18. Costa, E.L.; Borges, J.B.; Melo, A.; Suarez-Sipmann, F.; Toufen, C.J.; Bohm, S.H.; Amato, M.B. Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography. Intensive Care Med. 2009, 35, 1132–1137. [Google Scholar]
  19. Liu, K.; Huang, C.; Xu, M.; Wu, J.; Frerichs, I.; Moeller, K.; Zhao, Z. PEEP guided by electrical impedance tomography during one-lung ventilation in elderly patients undergoing thoracoscopic surgery. Ann. Transl. Med. 2019, 7, 757. [Google Scholar]
  20. Akand, M.; Erdogru, T.; Avci, E.; Ates, M. Transperitoneal versus extraperitoneal robot-assisted laparoscopic radical prostatectomy: A prospective single surgeon randomized comparative study. Int. J. Urol. 2015, 22, 916–921. [Google Scholar]
  21. Dal Moro, F.; Crestani, A.; Valotto, C.; Guttilla, A.; Soncin, R.; Mangano, A.; Zattoni, F. Anesthesiologic effects of transperitoneal versus extraperitoneal approach during robot-assisted radical prostatectomy: Results of a prospective randomized study. Int. Braz. J. Urol. 2015, 41, 466–472. [Google Scholar] [PubMed]
  22. Cochetti, G.; Del Zingaro, M.; Ciarletti, S.; Paladini, A.; Felici, G.; Stivalini, D.; Cellini, V.; Mearini, E. New evolution of robotic radical prostatectomy: A single center experience with PERUSIA technique. Appl. Sci. 2021, 11, 1513. [Google Scholar]
  23. Di Pierro, G.B.; Wirth, J.G.; Ferrari, M.; Danuser, H.; Mattei, A. Impact of a single-surgeon learning curve on complications, positioning injuries, and renal function in patients undergoing robot-assisted radical prostatectomy and extended pelvic lymph node dissection. Urology 2014, 84, 1106–1111. [Google Scholar] [PubMed]
  24. Paladini, A.; Cochetti, G.; Felici, G.; Russo, M.; Saqer, E.; Cari, L.; Bordini, S.; Mearini, E. Complications of extraperitoneal robot-assisted radical prostatectomy in high-risk prostate cancer: A single high-volume center experience. Front. Surg. 2023, 10, 1157528. [Google Scholar] [PubMed]
  25. Rohloff, M.; Cicic, A.; Christensen, C.; Maatman, T.K.; Lindberg, J.; Maatman, T.J. Reduction in postoperative ileus rates utilizing lower pressure pneumoperitoneum in robotic-assisted radical prostatectomy. J. Robot. Surg. 2019, 13, 671–674. [Google Scholar] [PubMed]
  26. Kobylianskii, J.; Murray, A.; Brace, D.; Goligher, E.; Fan, E. Electrical impedance tomography in adult patients undergoing mechanical ventilation: A systematic review. J. Crit. Care 2016, 35, 33–50. [Google Scholar] [PubMed]
  27. Zitzmann, A.; Pulletz, S.; Gonzales-Rios, P.; Frenkel, P.; Teschendorf, P.; Kremeier, P.; Loser, B.; Krukewitt, L.; Reuter, D.A.; Bohm, S.H.; et al. Regional ventilation in spontaneously breathing COVID-19 patients during postural maneuvers assessed by electrical impedance tomography. Acta Anaesthesiol. Scand. 2023, 67, 185–194. [Google Scholar]
  28. Futier, E.; Jaber, S. Lung-protective ventilation in abdominal surgery. Curr. Opin. Crit. Care 2014, 20, 426–430. [Google Scholar]
  29. Lagier, D.; Velly, L.J.; Guinard, B.; Bruder, N.; Guidon, C.; Vidal Melo, M.F.; Alessi, M. Perioperative open-lung approach, regional ventilation, and lung injury in cardiac surgery. Anesthesiology 2020, 133, 1029–1045. [Google Scholar]
  30. Young, C.C.; Harris, E.M.; Vacchiano, C.; Bodnar, S.; Bukowy, B.; Elliott, R.R.D.; Migliarese, J.; Ragains, C.; Trethewey, B.; Woodward, A.; et al. Lung-protective ventilation for the surgical patient: International expert panel-based consensus recommendations. Br. J. Anaesth. 2019, 123, 898–913. [Google Scholar]
  31. Muders, T.; Luepschen, H.; Zinserling, J.; Greschus, S.; Fimmers, R.; Guenther, U.; Buchwald, M.; Grigutsch, D.; Leonhardt, S.; Putensen, C.; et al. Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury. Crit. Care Med. 2012, 40, 903–911. [Google Scholar]
  32. PROVE Network Investigators. High versus low positive end-expiratory pressure during general anaesthesia for open abdominal surgery (PROVHILO trial): A multicentre randomised controlled trial. Lancet 2014, 384, 495–503. [Google Scholar]
  33. Shono, A.; Katayama, N.; Fujihara, T.; Böhm, S.H.; Waldmann, A.D.; Ugata, K.; Nikai, T.; Saito, Y. Positive end-expiratory pressure and distribution of ventilation in pneumoperitoneum combined with steep trendelenburg position. Anesthesiology 2020, 132, 476–490. [Google Scholar] [PubMed]
  34. Luecke, T.; Pelosi, P. Clinical review: Positive end-expiratory pressure and cardiac output. Crit. Care 2005, 9, 607–621. [Google Scholar] [PubMed]
  35. Vieillard-Baron, A.; Matthay, M.; Teboul, J.L.; Bein, T.; Schultz, M.; Magder, S.; Marini, J.J. Experts’ opinion on management of hemodynamics in ARDS patients: Focus on the effects of mechanical ventilation. Intensive Care Med. 2016, 42, 739–749. [Google Scholar]
  36. Serpa, N.A.; Hemmes, S.N.; Barbas, C.S.; Beiderlinden, M.; Fernandez-Bustamante, A.; Futier, E.; Hollmann, M.W.; Jaber, S.; Kozian, A.; Licker, M.; et al. Incidence of mortality and morbidity related to postoperative lung injury in patients who have undergone abdominal or thoracic surgery: A systematic review and meta-analysis. Lancet Respir. Med. 2014, 2, 1007–1015. [Google Scholar]
  37. Sribar, A.; Merc, V.; Persec, Z.; Persec, J.; Milas, I.; Husedzinovic, S. Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position. J. Clin. Monit. Comput. 2020, 34, 311–318. [Google Scholar]
  38. Hedenstierna, G. Gas exchange during anaesthesia. Br. J. Anaesth. 1990, 64, 507–514. [Google Scholar] [CrossRef]
  39. Miskovic, A.; Lumb, A.B. Postoperative pulmonary complications. Br. J. Anaesth. 2017, 118, 317–334. [Google Scholar]
Figure 1. Flowchart of patient enrollment. PEEPIND, individualized PEEP guided by electrical impedance tomography; PEEP5, standard PEEP setting of 5 cm H2O.
Figure 1. Flowchart of patient enrollment. PEEPIND, individualized PEEP guided by electrical impedance tomography; PEEP5, standard PEEP setting of 5 cm H2O.
Bioengineering 10 01172 g001
Table 1. Baseline characteristics of the study population.
Table 1. Baseline characteristics of the study population.
CharacteristicPEEP5 (n = 26)PEEPIND (n = 26)
Age (yr)65 (52–83)67.8 (53–80)
<65 [n (%)]13 (50)9 (34.6)
BMI (kg m−2)24.4 (2.1)24.1 (2.2)
ASA physical status
I3 (11.5)4 (15.4)
II22 (84.6)22 (84.6)
III1 (3.8)0 (0)
Hypertension (%)12 (46.2)7 (26.9)
Diabetes (%)3 (11.5)3 (11.5)
Total fluid infusion (mL)2063.5 ± 257.11932.7 ± 342
Blood loss (mL)124.2 ± 50.5123.1 ± 45.2
Urinary output (mL)357.7 ± 177330.8 ± 228.1
Vasoactive injections
Ephedrine (mg)6.7 ± 4.77.4 ± 6.6
Phenylephrine (μg)204.6 ± 223.7127.7 ± 176.5
Anesthesia duration (min)227.4 ± 35.1218 ± 34.1
Surgery duration (min)169.4 ± 29.3169.6 ± 27.4
PEEP (cm H2O)5 (5–5)16 (12–18)
Data are presented as mean ± SD, mean (range), or number (%). ASA, American Society of Anesthesiologists; BMI, body mass index; PEEP, positive end-expiratory pressure.
Table 2. Respiratory and hemodynamic parameters during mechanical ventilation.
Table 2. Respiratory and hemodynamic parameters during mechanical ventilation.
ParameterTime PointsPEEP5
(n = 26)
PEEPIND
(n = 26)
p-Value
PaO2/FiO2 (kPa)PEEP 5 min56.6 ± 9.063.8 ± 14.20.033
PEEP 60 min57.3 ± 14.465.5 ± 13.10.036
Pre-extubation56.8 ± 14.171.6 ± 10.70.003
Plateau pressure (cm H2O)PEEP 5 min21.3 ± 5.027.9 ± 4.330.000
PEEP 60 min21.3 ± 3.027.6 ± 4.20.000
Pre-extubation20.0 ± 4.427.5 ± 3.40.000
Driving pressure (cm H2O)PEEP 5 min14.2 ± 3.013.7 ± 3.60.586
PEEP 60 min15.8 ± 2.613.4 ± 4.10.014
Pre-extubation15.0 ± 4.412.0 ± 3.00.044
Cdyn (mL/cm H2O)PEEP 5 min32.6 ± 6.135.9 ± 7.00.076
PEEP 60 min29.6 ± 5.237.5 ± 9.20.000
Pre-extubation33.6 ± 9.144.5 ± 12.80.017
HRPEEP 5 min63.0 ± 8.964.4 ± 8.70.562
PEEP 60 min66.2 ± 10.061.4 ± 8.90.076
Pre-extubation66.2 ± 8.160.2 ± 8.10.080
SBPPEEP 5 min110.6 ± 13.3113.8 ± 12.00.363
PEEP 60 min114.9 ± 23.7117.5 ± 12.60.632
Pre-extubation117.9 ± 12.3123.8 ± 17.80.321
DBPPEEP 5 min59.8 ± 8.961.0 ± 6.90.579
PEEP 60 min60.3 ± 9.665.0 ± 10.20.088
Pre-extubation62.5 ± 8.365.9 ± 9.10.315
Data are presented as mean ± SD. PEEP 5 min, five minutes after PEEP setting; PEEP 60 min, 60 min after PEEP setting; Pre-extubation, before extubation but after operation; HR, heart rate; SBP, systolic blood pressure; DBP, diastolic blood pressure.
Table 3. Regional lung ventilation distribution.
Table 3. Regional lung ventilation distribution.
PEEPPwPb
PEEP5 (n = 26)PEEPIND (n = 26)
Ventral/dorsal distribution ratio
T01.09 (0.97–1.21)1.08 (0.96–1.19)0.0040.000
T11.39 (1.26–1.52)0.99 (0.86–1.12)
T22.00 (1.53–2.47)1.02 (0.57–1.47)
T31.27 (1.06–1.47)1.17 (0.97–1.37)
T0: before induction of anesthesia; T1: 5 min after PEEP setting; T2: 60 min after PEEP setting; T3: 10 min after extubation. Data are presented as means and 95% confidence interval two-factor repeated measures through ANOVA. Pw—within group interactions, Pb—between groups interactions with post hoc Bonferroni correction.
Table 4. Incidence of hypoxemia in the PACU.
Table 4. Incidence of hypoxemia in the PACU.
Total (n)Hypoxemia
[n (%)]
Non-Hypoxemia
[n (%)]
p-Value
PEEP5267 (26.9)19 (73.1)0.021
PEEPIND261 (3.8)25 (96.2)
Data are presented as numbers (%). PEEPIND, individualized PEEP setting guided by electrical impedance tomography; PEEP5, standard PEEP setting of 5 cm H2O. PACU, post-anesthesia care unit.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Pan, L.; Yang, L.; Gao, L.; Zhao, Z.; Zhang, J. Individualized PEEP without Recruitment Maneuvers Improves Intraoperative Oxygenation: A Randomized Controlled Study. Bioengineering 2023, 10, 1172. https://doi.org/10.3390/bioengineering10101172

AMA Style

Pan L, Yang L, Gao L, Zhao Z, Zhang J. Individualized PEEP without Recruitment Maneuvers Improves Intraoperative Oxygenation: A Randomized Controlled Study. Bioengineering. 2023; 10(10):1172. https://doi.org/10.3390/bioengineering10101172

Chicago/Turabian Style

Pan, Lili, Li Yang, Lingling Gao, Zhanqi Zhao, and Jun Zhang. 2023. "Individualized PEEP without Recruitment Maneuvers Improves Intraoperative Oxygenation: A Randomized Controlled Study" Bioengineering 10, no. 10: 1172. https://doi.org/10.3390/bioengineering10101172

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop