Next Article in Journal
E-Voting System Using Hyperledger Fabric Blockchain and Smart Contracts
Previous Article in Journal
Smart Bracelet for Emotional Enhancement in Children with Autism Spectrum Disorder
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Proceeding Paper

Study of Blood-Pressure Measurement Using Noninvasive Methods †

by
Mariña González-Pena
*,
Juan A. Castro-García
*,
Alberto J. Molina-Cantero
,
Manuel Merino-Monge
and
Isabel M. Gómez-González
Departamento de Tecnología Electrónica, ETS, Ingeniería Informática, Universidad de Sevilla, 41012 Sevilla, Spain
*
Authors to whom correspondence should be addressed.
Presented at the 4th XoveTIC Conference, A Coruña, Spain, 7–8 October 2021.
Eng. Proc. 2021, 7(1), 8; https://doi.org/10.3390/engproc2021007008
Published: 29 September 2021
(This article belongs to the Proceedings of The 4th XoveTIC Conference)

Abstract

:
The correct diagnosis of high blood pressure is important to avoid cardiovascular diseases. In this work, we propose a low-cost noninvasive blood-pressure measurement unit composed of a photoplethysmograph and an electrocardiograph. It is based on pulse transit time measurement, thus performing nonocclusive measurement. To test the effectiveness of this parameter, a total of five subjects were measured, verifying their effectiveness at all times.

1. Introduction

Cardiovascular diseases are a group of disorders related to the circulatory system that may affect the heart. According to the World Health Organisation World Health Organisation (WHO), 17.9 million people die from cardiopathy, with high blood pressure (BP) being one of the major risk factors for cardiovascular disease [1]. The periodic measurement of the BP is recommended. Some methods for it have the disadvantage of being occlusive, which may cause discomfort to patients, apart from requiring health personnel. In recent years, a method of BP measurement based on the pulse wave velocity (PWV) concept has been investigated, which has the great advantage of being nonocclusive.
PWV is defined as the velocity of pressure pulses as they propagate along the arterial tree. Any variation in the biomechanical properties of the aorta induces changes in pulse propagation velocity; see [2] for further details. In general, different proposals are based on the following simplification: given an arterial segment of length D, the PWV is defined as quotient of D divided by pulse transit time (PTT) P W V = D / P T T , where PTT isthe time of flight of the pressure wave. More exactly, P T T corresponds to the difference between the arrival times of the pressure pulse at the distal end and the proximity of the heart P T T = P A T d P A T p (see Figure 1). The wave peak R of the electrocardiography (ECG) offers information about when heart contraction starts. Thus, it represents to some extent P A T p time, while the systolic peak of the photoplethysmography (PPG) indicates the distal P A T d .

2. Materials and Methods

With the aim of quantifying the PTT, an Arduino shield called Galicia was developed. It contains an ECG and a PPG. An Arduino Uno, programmed using library BSP [3] at 256 Hz of sampling frequency, has only been used for data acquisition. The ECG circuit was presented in [4], with electrodes placed following the Einthoven lead II schema. The PPG is formed by an TCRT100, a high-pass filter with a cut-off frequency of 0.7 Hz, a low pass filter of 28.2 Hz, and a total gain of 100. In order to make the design portable, an external battery was added along with an expansion port for a Bluetooth connection through the HC05 module. Between the R peak of the ECG signal and the systolic peak of the PPG signal, there is a delay of the order of hundreds of milliseconds that remains constant throughout the measurement. This delay obeys the response time between the electrical activation of the myocardium and the mechanical ejection of the ventricular blood towards the aorta. In the ECG signal, the R peak is the most commonly used critical point, whereas for the PPG, there is no defined convention for this point. In this case, the maximum of the first derivative of the PPG signal, the so-called velocity of PPG (VPG), was chosen; this point is also known as D 1 . The Pan–Tompkins algorithm [5] is used for the detection of the R and D 1 points in offline processing.
The principal aim of the development of this study was to use the concept of PTT to estimate arterial BP, finding out the relationship among systolic pressure (SP), arm length, and PTT. In addition, the effect of physical exercise on BP reduction was analyzed to process ECG and PPG data taken from a total of five people (3 men and 2 women) with an age range of 22 to 34 years. Only one participant, S2, had been subjected to a 2.5 min of soft exercise before the corresponding measurements were taken, to verify that there was a decrease in BP [6].
The method is similar for both situations and comprises the following steps: (1) measurement of diastolic and SP before of the experiment using a sphygmomanometer; (2) arm-length measurement; (3) ECG and PPG data recorded for 2.5 min, and (4) measurement of diastolic and SP. During Step (3), all volunteers were at rest except in the physical condition, in which one volunteer was pedalling.

3. Results and Discussions

The following relationships were analysed: SP, arm length, and PTT. First, a higher PTT value is related to a higher BP, as Table 1 shows, where the participant with less arterial pressure was the one who had less PTT. The relationship between PTT and the ratio of SP to arm length (SPAL) was then analyzed. The definition of PTT shows that the lower the value of such a ratio is, the lower the PTT (SPAL in Table 1), with the exception of participant S2, who did not fulfil this condition. Therefore, the existence of a relationship between PTT and systolic pressure was demonstrated. According to the consulted bibliography, this relationship can be very useful in the detection of patients in a sleep unit since it provides relevant information about refractory hypertension [7].
Lastly, for participant S2 who was performing physical exercise for 2 min 30 s, blood pressure obtained prior and after working out was compared. PTT decreased when the subject underwent physical activity, which agreed with some published studies [8]. Although obtained results were conclusive with the consulted bibliography, they were not statistically significant since the tests were performed only on five people.
Two devices based on this technology are currently on the market: the ASUS VivoWatch BP and the RT1025 Cardioid PAD. Both integrate ECG and PPG sensors with a cost of EUR 139 and EUR 75.75, respectively. The price of these devices is far from the one designed for this work, which costs EUR 25.

4. Conclusions

In this work, we used the concept of PTT for the measurement of BP using electrocardiographic and photoplethysmographic signals. The relationship among concepts such as PTT, SP or PTT, and physical exercise were tested. In summary, the designed hardware device, PCB GALICIA, fulfilled the initial objective, being useful for analyzing PPG and ECG signals.

Funding

This research was funded by Spanish Ministry of Science and Innovation, State Plan 2017–2020: Challenges—R&D&I Projects with grant codes PID2019-104323RB-C32.

Institutional Review Board Statement

The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Ethics Committee of Junta de Andalucía (protocol code C.P. TAIS-C.I. 1130-N-17, 2018).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. World Health Organization. Cardiovascular Diseases (CVDs). 2021. Available online: https://www.who.int/en/news-room/fact-sheets/detail/cardiovascular-diseases-(cvds) (accessed on 8 September 2021).
  2. Solà i Carós, J.M. Continuous Non-Invasive Blood Pressure Estimation. Ph.D. Thesis, ETH Zurich, Zurich, Switzerland, 2011. [Google Scholar]
  3. Molina-Cantero, A.J.; Castro-García, J.A.; Lebrato-Vázquez, C.; Gómez-González, I.M.; Merino-Monge, M. Real-Time Processing Library for Open-Source Hardware Biomedical Sensors. Sensors 2018, 18, 1033. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Castro-García, J.A.; Molina-Cantero, A.J.; Merino-Monge, M.; Gómez-González, I.M. An Open-Source Hardware Acquisition Platform for Physiological Measurements. IEEE Sens. J. 2019, 19, 11526–11534. [Google Scholar] [CrossRef]
  5. Pan, J.; Tompkins, W.J. A Real-Time QRS Detection Algorithm. IEEE Trans. Biomed. Eng. 1985, BME-32, 230–236. [Google Scholar] [CrossRef] [PubMed]
  6. Ferrer Mileo, V. Estudio de la Viabilidad de la Estimación del Grado de Adherencia a Estilos de Vida Saludables a Partir de Medidas Cardíacas Oportunistas. Ph.D. Thesis, Universitat Politècnica de Catalunya, Barcelona, Spain, 2019. [Google Scholar]
  7. Gómez García, M.T.; Troncoso Acevedo, M.F.; Rodriguez Guzmán, M.; Alegre de Montaner, R.; Fernández Fernández, B.; del Río Camacho, G.; González-Mangado, N. Can Pulse Transit Time Be Useful for Detecting Hypertension in Patients in a Sleep Unit? Arch. Bronconeumol. 2014, 50, 278–284. [Google Scholar] [CrossRef] [PubMed]
  8. Mateu-Mateus, M.; Guede-Fernández, F.; García-González, M.A.; Ramos-Castro, J.J.; Fernández-Chimeno, M. Camera-Based Method for Respiratory Rhythm Extraction From a Lateral Perspective. IEEE Access 2020, 8, 154924–154939. [Google Scholar] [CrossRef]
Figure 1. ECG (blue), PPG (orangle), and VPG (purple). Signal amplitudes were normalized.
Figure 1. ECG (blue), PPG (orangle), and VPG (purple). Signal amplitudes were normalized.
Engproc 07 00008 g001
Table 1. BP, heart rate (HR), arm length, PTT and SPAL per participant.
Table 1. BP, heart rate (HR), arm length, PTT and SPAL per participant.
IDBP-Pre
(mmHg)
HR-Pre
(bpm)
BP-Post
(mmHg)
HR-Post
(bpm)
Arm Length
(m)
PTT
(ms)
SPAL
(mmHg/m)
1100/6791101/70830.700251143
2123/7467110/65610.855301144
3125/8183120/82830.830262151
4145/7286119/73610.835305174
5121/7758113/76580.730298165
2 e 112/7575103 /65640.855266131
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

González-Pena, M.; Castro-García, J.A.; Molina-Cantero, A.J.; Merino-Monge, M.; Gómez-González, I.M. Study of Blood-Pressure Measurement Using Noninvasive Methods. Eng. Proc. 2021, 7, 8. https://doi.org/10.3390/engproc2021007008

AMA Style

González-Pena M, Castro-García JA, Molina-Cantero AJ, Merino-Monge M, Gómez-González IM. Study of Blood-Pressure Measurement Using Noninvasive Methods. Engineering Proceedings. 2021; 7(1):8. https://doi.org/10.3390/engproc2021007008

Chicago/Turabian Style

González-Pena, Mariña, Juan A. Castro-García, Alberto J. Molina-Cantero, Manuel Merino-Monge, and Isabel M. Gómez-González. 2021. "Study of Blood-Pressure Measurement Using Noninvasive Methods" Engineering Proceedings 7, no. 1: 8. https://doi.org/10.3390/engproc2021007008

Article Metrics

Back to TopTop